Unique Systems Capability
- Fence Zoning
- Full Live Wire Fences
- LCD Keypads
- Selectable Zone Control
- Hi-Low Voltage Monitoring
- Pulse Synchronisation
- Smart Battery Backup
- Digital Voltage Display
- Purpose built design
The Electric Fence System
The system includes between 1-9, two channel ForceField® controllers and a keypad. Applications can include a maximum of 18 individual electric fence zones or 9 full live wire dual detection fence zones. Regulated pulses are monitored for cut, short, climb, tamper and cross coupling. Touching the electric fence will provide a short, sharp, safe electric shock. Each electric fence zone may be configured to monitor in Low Voltage mode providing monitoring of the electric fence integrity during normally disarmed time periods.
Full Live Wire Electric Fence
The ForceField® control units provide a unique ability to detect cross coupling of any two zones. This feature allows for every wire in the fencing system to not only be monitored but also provide a backup system should one zone be attacked ie. a full live wire electric fence system provides two levels of detection.
Individual Zone Control Commercial Fencing
Each ForceField® channel or zone may be armed individually in both high voltage and low voltage modes. This allows for total control for access or servicing of individual areas around the electric fence site.
Keypad The intelligent LCD keypad displays information regarding all programmable options of the ForceField® controller. Features such as arming/disarming the electric fence, area control and real time voltage are displayed on the keypads large graphic display.
Purpose Built and Designed Security Fencing
Each of the ForceField® controller components have been designed specifically for the function it performs, optimising the system for ease of use, installation and service throughout its life span.
Electric Fence System Features
- Full live wire fences with two levels of alarm.
- Low Power mode for continuous electric fence monitoring.
- Fully integrated up to 18 zones.
- RS485 via RJ12 (telecom connector) for LCD keypad.
- LCD Keypad for installation configuration and user display and control.
- Three isolated remote control inputs.
- Five user assignable relays which default to useable options.
- Expansion header for RF link and other future options.
- 2.0 joules output energy per channel.
- Selectable Zone Control.
- Pulse synchronisation.
- Industrial wall mounting IP55 polycarbonate case large enough to include 7aH battery. Dry contact alarm relays with both changeover contacts available.
- Many digitally adjustable parameters including electric fence voltage alarm level via optional user keypad.
- Fail-safe relays (General and Fence relays are normally energised to indicate a "no alarm" condition).
- Integrated battery charger for un-interruptible operation from a backup 12V battery.
- AC fail, Low Battery and Bad Battery detection.
- Alarm log event register.
- Adjustable energiser power output level.
- Inbuilt enclosure tamper detection.
Technical Specifications
Specification Name |
Specification |
Energiser output voltage |
8.5kV peak no load, 2.OJ at 500R |
Temperature Range |
-10° to 45° celsius |
Pulse Rate |
Crystal locked at 0.8 Hz |
12V DC Power Consumption |
Energiser On - 570mA (average)
Energiser Off - 100mA |
Battery Charger AC Power Input |
16-18 Vac 1A recommended |
Standby Current |
105mA |
Weight |
3.2kg Excluding battery |
LCD Keypad |
Intelligent LCD graphic, backlit with soft key function |
Keypad Cable Distance |
Up to 300m |
Battery Charger Output |
Float voltage 13.8V, 300mA short circuit protection |
Back Up Battery |
12 Volt 7Ah minimum 8 hrs back up |
Control Inputs |
Suitable for potential free (dry) contacts or switched 5-12V. See input table. 3 per controller. |
Relay Outputs |
Isolated dry contact, change over, relay rated at 1A 30V, 5 per controller |
Number of controllers, zones |
1-9 controllers, 2-18 HV and LV Zones |
Enclosure |
IP55 300mm x 220mm x 150mm |
|